Hydrotech's Monolithic Membrane 6125® (MM6125®), Standard Guideline Specifications and Standard Guideline Details for both waterproofing and roofing applications are on this page. Use the links below to move quickly to the selection you require. These specs and details are also available from Hydrotech on CD, diskette or via email. If you have any questions, please contact Hydrotech's Technical Services Department at 1-800-877-6125 for assistance, or by email.
The suitability of any of these specifications and details for a specific application should be reviewed by a design professional. These details cover typical conditions that one would expect to find on most waterproofing or roofing applications. If a typical detailing conditions exist contact Hydrotech's Technical Services Department for assistance.
SPECIFICATIONS...
Specifications (US/Domestic)
International Specifications
These specifications are the most up-to-date versions of these documents available from Hydrotech and supersede any previously versions issued (in print or electronic format). Hydrotech's standard specifications for waterproofing and roofing are provided in the popular Microsoft Word format.
DETAILS...
These details are the most up-to-date versions of these documents available from Hydrotech and supersede any previously versions issued (in print or electronic format). Hydrotech's standard guideline details are provided as individual Autodesk "DWG" format CAD details and in Adobe Acrobat "PDF" file format. All of the "DWG" CAD detail files are available also as a single compressed zip file.
A DWG file viewer is available for free download at Informative Graphics' website. Just click on this link to download it... |
|
Adobe's Acrobat Reader is available free from their website. Just click on this link to download it...
|
|
|
|
MM6125 SPECIFICATIONS...
(To download: Click the right mouse button and select "Save Target As…")
Type of
Application
|
Standard
Assembly *
|
Fabric Reinforced Assembly **
|
|
(new construction only) |
(new construction, rehab & long term warranties) |
| Waterproofing |
|
|
| Roofing |
|
|
| Ultimate Plaza/Roof Terrace Assembly |
-- |
|
| Garden Roof Assembly (Extensive) |
-- |
|
| Garden Roof Assembly (Intensive) |
-- |
|
| Garden Roof Assembly (Shallow-Intensive) |
-- |
|
| Garden Roof Assembly (Steep Slope) |
-- |
|
* The Standard Assembly consists of 180 mil thick, one coat application and is acceptable for new construction only. For extended and total assembly warranties refer to the Fabric Reinforced Assembly.
** The Fabric Reinforced Assembly consists of 215 mil thick, reinforced membrane and is acceptable in all applications and assemblies, required where long term warranties are requested.
MM6125 Waterproofing Details...
Detail #
|
Description
|
File Type
|
File Type
|
All
|
Complete set of MM6125-FR Waterproofing Details
|
|
|
| All |
Index of Pages |
|
|
| W-01 |
Material Application |
|
|
| W-02A |
Typical Applications |
|
|
| W-02B |
Typical Applications |
|
|
| W-03 |
General Concrete Crack And Joint Treatment |
|
|
| W-04 |
Concrete Construction Joints |
|
|
| W-05A |
Precast Concrete Plank/Panel Joint Treatment |
|
|
| W-05B |
Precast Plank/Panel W/Topping Slab Treatment |
|
|
| W-06A |
Expansion Joint Up To 1" As-Built Width |
|
|
| W-06B |
Field Expansion Joint 1"-2" Max. As-Built Widths |
|
|
| W-06C |
Deck-To-Wall Expansion Joint 1"-2" Max. As-Built Widths |
|
|
| W-06D |
Alternate Prefabricated Expansion Joints |
|
|
| W-07A |
Typical Cast In Place Penetrations (Pipe, Conduit, etc.) |
|
|
| W-07B |
Typical Non Cast-In-Place Penetrations (Pipe, Vent, etc.) |
|
|
| W-08A |
Typical Drain Details |
|
|
| W-08B |
Typical Drain Details |
|
|
| W-09 |
Typical Curb Details |
|
|
| W-10A |
Typical Planter Applications |
|
|
| W-10B |
Typical Planter Details |
|
|
| W-11A |
Typical Foundation Wall Applications |
|
|
| W-11B |
Typical Foundation Wall Detailing At Grade |
|
|
| W-11C |
Typical Foundation Wall Detailing At Footing |
|
|
| W-12 |
Alternate Corner Transitions |
|
|
| W-13A |
Inside Corner Reinforcement |
|
|
| W-13B |
Outside Corner Reinforcement |
|
|
| W-14A |
Typical Tie-In Details |
|
|
| W-14B |
Typical Tie-In Details |
|
|
MM6125 Roofing Details...
Detail #
|
Description
|
File Type
|
File Type
|
All
|
Complete set of MM6125-FR Roofing Details
|
|
|
| All |
Index of Pages |
|
|
| R-01 |
Material Application |
|
|
| R-02 |
General Crack And Joint Treatment |
|
|
| R-03 |
Concrete Construction Joints |
|
|
| R-04A |
Precast Concrete Plank/Panel Joint Treatment |
|
|
| R-04B |
Precast Plank/Panel W/Topping Slab Treatment |
|
|
| R-05A |
Alternate Substrate Applications |
|
|
| R-05B |
Additional Alternate Substrate Applications |
|
|
| R-06A |
Expansion Joint Up To 1" As-Built Widths |
|
|
| R-06B |
Field Expansion Joint 1"-2" Max. As-Built Width |
|
|
| R-06C |
Alternate Prefabricated Deck-To-Wall Expansion Joints |
|
|
| R-06D |
Deck-To-Wall Expansion Joint 1"-2" Max. As-Built Widths |
|
|
| R-06E |
Alternate Prefabricated Deck To Wall Expansion Joints |
|
|
| R-07A |
Typical Cast In Place Penetrations & Pitch Pocket (Pipe/Vent) |
|
|
| R-07B |
Typical Non Cast-In-Place Penetrations (Pipe/Vent) |
|
|
| R-08 |
Typical Drain Details |
|
|
| R-09 |
Typical Curb Details |
|
|
| R-10 |
Typical Davit Detail |
|
|
| R-11A |
Typical Parapet - Covered Flashing Conditions |
|
|
| R-11B |
Typical Parapet - Exposed Flashing Conditions |
|
|
| R-11C |
Typical Parapet - Gypsum Board/Metal Deck Substrate |
|
|
| R-11D |
Typical Parapet - At Precast Wall |
|
|
| R-11E |
Typical Parapet - At Precast Wall |
|
|
| R-12 |
Alternate Flashing Corner Transitions |
|
|
| R-13 |
Alternate Flashing Terminations |
|
|
| R-14 |
Roof Edge Termination - Typical Gravel/Paver Stop |
|
|
| R-15A |
Thru-Wall Scupper Flashing |
|
|
| R-15B |
Overflow Scupper Flashing |
|
|
| R-16A |
Inside Corner Reinforcement |
|
|
| R-16B |
Outside Corner Reinforcement |
|
|
| R-17A |
Typical Tie-In Details (Curbed) |
|
|
| R-17B |
Typical Tie-In Details (Horizontal) |
|
|
| R-17C |
Typical Tie-In Details (Thru-Wall/Air Barrierl) |
|
|
Ultimate Plaza/Terrace Assembly Details...
Detail #
|
Description
|
File Type
|
File Type
|
All
|
Complete set of Ultimate Plaza/Terrace Details
|
|
|
| All |
Index of Pages |
|
|
| UA-1 |
Typical Termination At Wall/Parapet/Curb |
|
|
| UA-2 |
Typical Termination W/Adjustable Pedestal At Wall/Parapet/Curb |
|
|
| UA-3 |
Additional Adjustable Pedestal Extension Materials |
|
|
| UA-4 |
Cantilevered Termination |
|
|
| UA-5A |
Installation Detail At Drains |
|
|
| UA-5B |
Installation At Drain Isometric Layout |
|
|
| UA-6 |
Rock Curb Standard Precast |
|
|
Garden Roof Assembly Details...
Detail #
|
Description
|
File Type
|
File Type
|
All
|
Complete set of MM6125 Garden Roof Assembly Details
|
dwg zip
|
|
| All |
Index of Pages |
|
|
| GR-1A |
Typical Standard Garden Roof Assemblies |
|
|
| GR-1B |
Typical Standard Garden Roof Assemblies |
|
|
| GR-2A |
Typical Extensive Garden Roof Term. Detail (i.e., Wall, Curb, Pipe) |
|
|
| GR-2B |
Typical Ext. Garden Roof Term. Detail Max. Water Retention |
|
|
| GR-2C |
Typical Garden Roof Termination Perimeter Parapet (High Wind) |
|
|
| GR-3 |
Typical Intensive Garden Roof Term. Detail (i.e., Wall, Curb, Pipe) |
|
|
| GR-4 |
Typical Drain |
|
|
| GR-5A |
Generic Transition Option Garden Roof / Ballasted Roof |
|
|
| GR-5B |
Transition Option Garden Roof / Timbers / Pavers |
|
|
| GR-5C |
Transition Option Garden Roof / Rock Curb / Ultimate Assembly |
|
|
| GR-5D |
Another Transition Option Garden Roof/Rock Curb/Ultimate Assembly |
|
|
| GR-5E |
Transition Option Garden Roof / Concrete Curb / Ultimate Assembly |
|
|
| GR-5F |
Transition Option Garden Roof / Precast Wall / Ultimate Assembly |
|
|
| GR-6 |
Suggested Contoured Soil Mound Placement w/ Geofill |
|
|
| GR-7 |
Root Stop HD/Bamboo Typical Transition |
|
|
| GR-8 |
Typical GardNet Section Details |
|
|
| GR-9 |
Typical GardNet Tendon Spacing |
|
|
| GR-10A |
Typical Top of Slope GardNet Connection |
|
|
| GR-10B |
Another Typical Top of Slope GardNet Connection |
|
|
| GR-10C |
Typical Top of Slope GardNet Connection @ Ridge |
|
|
| GR-10D |
Typical Top of Slope Double Layer GardNet Connection |
|
|
| GR-11A |
Typical Bottom of Slope GardNet Termination |
|
|
| GR-11B |
Another Typical Bottom of Slope GardNet Termination |
|
|
| GR-12 |
GardNet Wing Tendons and Spacers |
|
|
| GR-13 |
GardNet Adjacent Section Attachment |
|
|
If you should have any questions regarding Hydrotech, our products, or if we can be of any assistance on your next tough (or easy) waterproofing or roofing project, please don't hesitate to contact us...
|