Monolithic Membrane 6125 (MM6125®) is a thick, tough, flexible, self-healing membrane for use in waterproofing and roofing applications. MM6125 is a special formulation of refined asphalts and synthetic rubbers. MM6125 has been successfully used worldwide by leading architects, engineers and owners on all types of horizontal and vertical structures including plazas, parking decks, planters, tunnels, bridges, mud slabs, foundation walls and roof areas...establishing an unbeatable 35 year track record.
MM6125 has many unique characteristics...
- MM6125 is a thermoplastic material - one component, 100% solids, no solvents means no on-site cure failures, no two part mixing and no VOC restrictions.
- MM6125 conforms to all surface irregularities and bonds tenaciously to an acceptable substrate (i.e., concrete, steel, wood, etc.) eliminating lateral migration of water.
- MM6125 is completely monolithic, no seams!
- MM6125 is typically installed at 215 mils thick in the Fabric Reinforced Assembly. This is more than three times thicker than most other waterproofing membranes. Thickness is an important benefit in that MM6125 exhibits the ability to self-heal and better accommodate developing cracks in a concrete substrate.
- MM6125 can be installed at 180 mils thick in the Standard Assembly - please contact Hydrotech for specifics.
- MM6125 can be installed at temperatures as low as 0 °F (provided the substrate is clean, dry, free of snow and frost).
- MM6125 detailing is simplified, with triple protection at all critical locations.
One of the reasons MM6125 has been so successful in the market place is that MM6125 can only be installed by "trained" authorized Hydrotech applicators. MM6125 is sold direct, not through a distributorship (or over the counter).
MM6125 Approvals/Certifications...
- ISO 9001-2000
- CAN/CGSB 37.50-M89 (Canadian General Standards Board)
- Applicable ASTM Test Methods (American Society for Testing and Materials)
- BBA Approval (British Board of Agrément)
- UL Class A Classification (Underwriter Laboratories)
- FM Approval (Factory Mutual)
- Dade County, FL Approval
- General Approval - City of Los Angeles
- MEA Approval - City of New York
MM6125 Physical Properties...
| PROPERTY |
TEST METHOD |
TYPICAL RESULTS |
| Flash Point
| ASTM D-92, CGSB-37.50-M89 |
500 °F (260 °C)* |
| Low Temperature Crack Bridging Capability |
CGSB-37.50-M89 |
No cracking, adhesion loss, or splitting |
| Water Vapor Permeability |
ASTM E 96, Procedure E, CGSB-37.50-M89 |
1.6 ng/Pa(s)M², (0.018 perm) |
| Water Resistance (5 days/50 °C) |
CGSB-37.50-M89 |
No delamination, blistering, emulsification, or deterioration |
| Water Absorption |
CGSB-37.50-M89 |
0.22 g weight gain |
| Toughness |
CGSB-37.50-M89 |
13.0 Joules |
| Ratio of Toughness to Peak Load |
CGSB-37.50-M89 |
0.069 |
| Viscosity |
CGSB-37.50-M89 |
7.0 seconds |
| Heat Stability |
CGSB-37.50-M89 |
No change in viscosity, penetration, flow or low temperature flexibility |
Low Temperature Flexibility
( - 25 °C) |
CGSB-37.50-M89 |
No delamination, flexibility adhesion loss, or cracking |
| Penetration |
ASTM D 1191, CGSB-37.50-M89 |
75.0 mm @ 77 °F (25 °C), 121.7 mm @ 122 °F (50 °C) |
| Flow |
ASTM D 1191, GSB-37.50-M89 |
0.0 mm @ 140 °F (60 °C) |
| Softening Point |
ASTM D 36 |
180 °F (82 °C) |
| Elongation |
ASTM D 1191 |
1000 % minimum |
| Resiliency |
ASTM D 3407 |
40% minimum |
Bond to Concrete @ 0 °F,
( 18 °C) |
ASTM D 3408 |
Pass |
| Hydrostatic Pressure Resistance |
ASTM D-08.22, Draft 2 |
100 psi
(=231 foot head of water) |
| Acid Resistance |
ASTM D 896 Procedure 7.1 (N-8) |
Pass 50% Nitric Acid, 50% Sulfuric Acid |
Salt Water Resistance
(20% sodium carbonate
and calcium chloride) |
ASTM D-896 similar |
No delamination, blistering, emulsification, or deterioration |
Fertilizer Resistance
(undiluted 15/5/5 nitrogen /phosphorus/potash) |
ASTM D-896 similar |
No delamination, blistering, emulsification, or deterioration |
| Animal Waste Resistance |
3 year exposure |
No deterioration |
| Solids Content |
|
100% no solvents |
| Shelf Life |
|
10 years (sealed) |
| Specific Gravity |
|
1.23 ± .02 |
| 45 °F more than the application temperature recommended by the manufacturer. |
If you should have any questions regarding Hydrotech, our products, or if we can be of any assistance on your next tough (or easy) waterproofing or roofing project, please don't hesitate to contact us...
|
MM6125 Product Brochure |
|
MM6125 Product Data Sbeet |
|
|
|
|
|
| |
|
|
|
|